Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

GLDC CLIA Kit

Human GLDC ELISA Kit Chemiluminescent assay for quantification of Human GLDC.
Catalog No. ABIN5654738

Quick Overview for GLDC CLIA Kit (ABIN5654738)

Target

See all GLDC CLIA Kits
GLDC (Glycine Dehydrogenase (GLDC))

Reactivity

  • 2
  • 2
  • 1
Human

Detection Method

Chemiluminescent

Method Type

Sandwich ELISA

Detection Range

156.25 pg/mL - 10000 pg/mL

Application

ELISA

Sample Type

Cell Lysate, Tissue Homogenate
  • Minimum Detection Limit

    156.25 pg/mL

    Analytical Method

    Quantitative

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Glycine Dehydrogenase (GLDC). No significant cross-reactivity or interference between Glycine Dehydrogenase (GLDC) and analogues was observed.

    Sensitivity

    4.7 pg/mL
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time

    2 - 3 h

    Plate

    Pre-coated

    Protocol

    The microplate provided in this kit has been pre-coated with an antibody specific to Glycine Dehydrogenase (GLDC). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Glycine Dehydrogenase (GLDC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Glycine Dehydrogenase (GLDC) level in the sample or standard.,

    Assay Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycine Dehydrogenase (GLDC) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycine Dehydrogenase (GLDC) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Handling Advice

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Storage

    4 °C,-20 °C

    Storage Comment

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Expiry Date

    4-8 months
  • Target See all GLDC CLIA Kits

    GLDC (Glycine Dehydrogenase (GLDC))

    Alternative Name

    Glycine Dehydrogenase

    Background

    Gene Name: Glycine Dehydrogenase

    Gene Aliases: GCSP, NKH, Decarboxylating, Glycine Decarboxylase, Glycine Cleavage System Protein P, Glycine dehydrogenase (aminomethyl-transferring)

    Gene ID

    2731

    UniProt

    P23378
You are here: